BRIDGE TECHNOLOGY

ESA Series

ESA Series

Programmable AC Power Supply

§ 30kVA - 2MVA and above

§ Output power: single system 30-240KVA, and parallel up to 960KVA and higher

§ 4 quadrant operation, regenerative up to 100% of rated output power back to grid (-R option)

§ Independent three-phase output

§ Up to 50th harmonic waveform generation

§ Soft start: effectively restrain the impulse current when power on

§ Voltage drop simulation (LVRT for inverter test)

§ Regenerative AC load function (-LD option)

§ Line impedance (RL) simulation (-IMP option)

§ Voltage and frequency sequencing programming via GUI, slew rate can be programmed

§ ON and OFF output phase angle can be programmed

§ Current limit can be programmed, output can be shorted for short circuit test

§ Triger out, TTL signal output for voltage or frequency change

§ Extend output frequency to DC (-DC option)

§ Add single phase output (-1P option)

§ Use water-cooling (-W option)

§ Master-Slave interface (-MS option)

§ Change to transformer output topology (-TR option)

§ TFT-Touch panel operation

§ LAN/RS485 interfaces (standard), RS232/Analog control interfaces (optional)

§ Mod-bus/SCPI protocols

§ Emergency stop button

§ Output contactor

§ Remote sense

§ CE conformity

ESA-E Datasheet 4.4 (EN).pdf
4.74MBDownload
ESA Datasheet 4.4 (EN).pdf
4.43MBDownload
ESA User Manual.pdf
2.34MBDownload
ESA SCPI Programming Manual.pdf
671.49KBDownload
ESA Demo Software.zip
6.25MBDownload
Prev 1 Next
ESA Series

ESA Series

副标题

BriPower ESA series uses bi-directional design, which makes it possible to be used as AC power source or regenerative AC load. It can be used as grid simulator in varieties of applications such as in Smart Grid, Energy Storage, Solar etc. ESA Series is highly customizable in Power, Voltage, Current and Frequency range to optimize to your application and budget. The source can be also configured with constant output haracteristics defined by your application. With touch panel on the front panel, user can control the power source with GUI software. System status indicators and emergency stop button are installed on the front panel. Programming interfaces including RS485 and LAN interfaces are standard, and optional RS232, analog interfaces are available for automated test applications.
Models (standard)

Models (standard)

副标题

AC Input Configuration

Please specify the input voltage (L-L)


-208, Input Voltage 208V±10%, 3-phase

-230, Input Voltage 230V±10%, 3-phase

-380, Input Voltage 380V±10%, 3-phase

-400, Input Voltage 400V±10%, 3-phase

-480, Input Voltage 480V±10%, 3-phase

ESA Options

ESA Options

副标题